Back to top

EL9000 Series

Discontinued

Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter

UL 60950
Wide Temperature
NEMA-TS2
UL Class 1 Division 2
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
Link Fault Pass Through (LFPT)
Alarms for power and link failure
Certified as Class I, Division 2 electrical equipment
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
EL9000 Series Hardened 1000BASE-T to 1000BASE-SX/LX/BX Media Converter
Overview
Spotlight
Specifications
Application
Dimensions
Ordering Info
This product is discontinued as of 31th July 2021. Click here for alternative product.

The EL9000 Series provides media conversion between 1000BASE-T(X) and 1000BASE-SX-LX Fiber. Built specifically for missioncritical applications in harsh environments, the EL9000's hardened design features high shock & vibration resistance, electrical noise immunity, wide operating temperature range from -40°C to 75°C, and ruggedized aluminum housing. With triple power inputs, link down alarming, Link-Fault-Pass-Through and a wide range of fiber connectivity options, the EL9000 is the ideal media converter for environments where connectivity is crucial.

EtherWAN — "When Connectivity is Crucial."

Gigabit Connectivity

» 1000BASE-TX and 1000BASE-SX/LX/BX Ethernet transmission conversion
» 1000Mbps Full duplex and full wire-speed forwarding rate

ISA12.12.01 Certification

» Highly qualified for explosive environmental applications and certified by UL with ISA12.12.01 Class I, Division 2 classified for use in hazardous locations

Wide Operating Temperature

» -40°C to 75°C wide operating temperature range design is suitable for installation in outdoor cabinet

Technology

Standards

  • • IEEE802.3ab 1000BASE-T
  • • IEEE802.3z 1000BASE-SX/1000BASE-LX
  • • IEEE802.3x full duplex and flow control

Forward and Filtering Rate
  • • 1,488,100pps for 1000Mbps

Processing Type
  • • Auto Negotiation
  • • Half duplex back-pressure and IEEE802.3x full-duplex flow control
  • • Auto-MDI/MDIX

 


Power

Input Voltage

  • • 12 to 48VDC (Terminal Block)
  • • 12VDC (DC Jack)

Power Consumption
Protection
  • • Overload current protection
  • • Reverse polarity protection

 


Mechanical

Casing

  • • Aluminum Case
  • • IP30

Dimensions
  • • 50mm (W) x 110mm (D) x 135mm (H)
      (1.97" (W) x 4.33" (D) x 5.31" (H))

Weight
  • • 0.8Kg (1.76lbs.)

Installation
  • • DIN-Rail (Top hat type 35mm), Panel, or Rack mounting

 


Interface

Ethernet Port

  • • 1000BASE-T: 1 port
  • • 1000BASE-SX/LX: 1 port

LED Indicators
  • • Per Unit: Power, Power2, Fault
  • • Per Port: LNK, TX, RX

DIP Switch
  • • No.1: LFPT on/off
  • • No.2: Auto-negotiation for fiber port on/off
  • • No.3: Alarm for copper port on/off
  • • No.4: Alarm for fiber port on/off

Alarm Contact
  • • Relay contact rating with current 1A @ 30VDC, 0.5A @ 120VAC

 


Environment

Operating Temperature

  • • -40°C to 75°C (-40°F to 167°F)
      Tested @ -40°C to 85°C (-40°F to 185°F)

Storage Temperature
  • • -40°C to 85°C (-40°F to 185°F)

Ambient Relative Humidity
  • • 5% to 95% (non-condensing)

 


Regulatory Approvals

ISO

  • • Manufactured in an ISO 9001 facility

EMI
  • FCC Part 15B Class A
  • VCCI Class A
  • EN 55022
  • EN 61000-3-2
  • EN 61000-3-3
  • EN 61000-6-3

Safety
  • ISA 12.12.01 (UL1604) for Hazardous Locations
    • • Class 1, Division 2 group A,B,C&D
  • UL 60950-1

EMS
  • EN 61000-6-2
    • • EN 61000-4-2 (ESD Standards)
    • • EN 61000-4-3 (Radiated RFI Standards)
    • • EN 61000-4-4 (Burst Standards)
    • • EN 61000-4-5 (Surge Standards)
    • • EN 61000-4-6 (Induced RFI Standards)
    • • EN 61000-4-8 (Magnetic Field Standards)

Environmental Test Compliance
  • IEC 60068-2-6 Fc (Vibration Resistance)
  • IEC 60068-2-27 Ea (Shock)
  • FED STD 101C Method 5007.1 (Free fall w/ package)

Industrial Compliance
  • NEMA TS2

 


Model - Buy Now

EL9000-A-Y-1-P 1000BASE-T to 1000BASE-SX/LX Hardened Media Converter

Gigabit Fiber Options (Y)

B 1000BASE-SX (SC) - 550m (850nm)
C 1000BASE-SX (SC) - 2Km (1310nm)
N 1000BASE-LX (SC) - 10Km (1310nm)
O 1000BASE-LX (SC) - 20Km (1310nm)
R 1000BASE-BX (SC) WDM-TX: 1310nm/RX: 1550nm-20Km
S 1000BASE-BX (SC) WDM-TX: 1550nm/RX: 1310nm-20Km

* More Gigabit options are also available upon request.


Power Connector Options (P)

A Terminal Block
B DC Jack

Optional Accessories

KP-AA96-480 Panel mount kit
HDR-30-24 30W/1.5A DIN-Rail 24VDC Industrial Power Supply
HDR-60-24 60W/2.5A DIN-Rail 24VDC Industrial Power Supply
EDR-75-24 75W/3.2A DIN-Rail 24VDC Industrial Power Supply
EX41-145046-X Power Supply 45W 12VDC with Open Wire
(X) = 1: US, 2: EU, 3: UK, 4: AU, 5: JP, 6: SA
EX41-145044-X Power Supply 45W 12VDC with Latch
(X) = 1: US, 2: EU, 3: UK, 4: AU, 5: JP, 6: SA

Overview
This product is discontinued as of 31th July 2021. Click here for alternative product.

The EL9000 Series provides media conversion between 1000BASE-T(X) and 1000BASE-SX-LX Fiber. Built specifically for missioncritical applications in harsh environments, the EL9000's hardened design features high shock & vibration resistance, electrical noise immunity, wide operating temperature range from -40°C to 75°C, and ruggedized aluminum housing. With triple power inputs, link down alarming, Link-Fault-Pass-Through and a wide range of fiber connectivity options, the EL9000 is the ideal media converter for environments where connectivity is crucial.

EtherWAN — "When Connectivity is Crucial."

Spotlight

Gigabit Connectivity

» 1000BASE-TX and 1000BASE-SX/LX/BX Ethernet transmission conversion
» 1000Mbps Full duplex and full wire-speed forwarding rate

ISA12.12.01 Certification

» Highly qualified for explosive environmental applications and certified by UL with ISA12.12.01 Class I, Division 2 classified for use in hazardous locations

Wide Operating Temperature

» -40°C to 75°C wide operating temperature range design is suitable for installation in outdoor cabinet

Specifications

Technology

Standards

  • • IEEE802.3ab 1000BASE-T
  • • IEEE802.3z 1000BASE-SX/1000BASE-LX
  • • IEEE802.3x full duplex and flow control

Forward and Filtering Rate
  • • 1,488,100pps for 1000Mbps

Processing Type
  • • Auto Negotiation
  • • Half duplex back-pressure and IEEE802.3x full-duplex flow control
  • • Auto-MDI/MDIX

 


Power

Input Voltage

  • • 12 to 48VDC (Terminal Block)
  • • 12VDC (DC Jack)

Power Consumption
Protection
  • • Overload current protection
  • • Reverse polarity protection

 


Mechanical

Casing

  • • Aluminum Case
  • • IP30

Dimensions
  • • 50mm (W) x 110mm (D) x 135mm (H)
      (1.97" (W) x 4.33" (D) x 5.31" (H))

Weight
  • • 0.8Kg (1.76lbs.)

Installation
  • • DIN-Rail (Top hat type 35mm), Panel, or Rack mounting

 


Interface

Ethernet Port

  • • 1000BASE-T: 1 port
  • • 1000BASE-SX/LX: 1 port

LED Indicators
  • • Per Unit: Power, Power2, Fault
  • • Per Port: LNK, TX, RX

DIP Switch
  • • No.1: LFPT on/off
  • • No.2: Auto-negotiation for fiber port on/off
  • • No.3: Alarm for copper port on/off
  • • No.4: Alarm for fiber port on/off

Alarm Contact
  • • Relay contact rating with current 1A @ 30VDC, 0.5A @ 120VAC

 


Environment

Operating Temperature

  • • -40°C to 75°C (-40°F to 167°F)
      Tested @ -40°C to 85°C (-40°F to 185°F)

Storage Temperature
  • • -40°C to 85°C (-40°F to 185°F)

Ambient Relative Humidity
  • • 5% to 95% (non-condensing)

 


Regulatory Approvals

ISO

  • • Manufactured in an ISO 9001 facility

EMI
  • FCC Part 15B Class A
  • VCCI Class A
  • EN 55022
  • EN 61000-3-2
  • EN 61000-3-3
  • EN 61000-6-3

Safety
  • ISA 12.12.01 (UL1604) for Hazardous Locations
    • • Class 1, Division 2 group A,B,C&D
  • UL 60950-1

EMS
  • EN 61000-6-2
    • • EN 61000-4-2 (ESD Standards)
    • • EN 61000-4-3 (Radiated RFI Standards)
    • • EN 61000-4-4 (Burst Standards)
    • • EN 61000-4-5 (Surge Standards)
    • • EN 61000-4-6 (Induced RFI Standards)
    • • EN 61000-4-8 (Magnetic Field Standards)

Environmental Test Compliance
  • IEC 60068-2-6 Fc (Vibration Resistance)
  • IEC 60068-2-27 Ea (Shock)
  • FED STD 101C Method 5007.1 (Free fall w/ package)

Industrial Compliance
  • NEMA TS2

 


Application

Dimensions

Ordering Info

Model - Buy Now

EL9000-A-Y-1-P 1000BASE-T to 1000BASE-SX/LX Hardened Media Converter

Gigabit Fiber Options (Y)

B 1000BASE-SX (SC) - 550m (850nm)
C 1000BASE-SX (SC) - 2Km (1310nm)
N 1000BASE-LX (SC) - 10Km (1310nm)
O 1000BASE-LX (SC) - 20Km (1310nm)
R 1000BASE-BX (SC) WDM-TX: 1310nm/RX: 1550nm-20Km
S 1000BASE-BX (SC) WDM-TX: 1550nm/RX: 1310nm-20Km

* More Gigabit options are also available upon request.


Power Connector Options (P)

A Terminal Block
B DC Jack

Optional Accessories

KP-AA96-480 Panel mount kit
HDR-30-24 30W/1.5A DIN-Rail 24VDC Industrial Power Supply
HDR-60-24 60W/2.5A DIN-Rail 24VDC Industrial Power Supply
EDR-75-24 75W/3.2A DIN-Rail 24VDC Industrial Power Supply
EX41-145046-X Power Supply 45W 12VDC with Open Wire
(X) = 1: US, 2: EU, 3: UK, 4: AU, 5: JP, 6: SA
EX41-145044-X Power Supply 45W 12VDC with Latch
(X) = 1: US, 2: EU, 3: UK, 4: AU, 5: JP, 6: SA