Back to top

ED3638

強固級10/100BASE-TX PoL™/PoE乙太網路交換器(同軸電纜)

PoE_30W
UL 60950
ED3638TR : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638T : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638R : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_top
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_bottom
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_back
Power over Link up to 1.8 km (5905 ft.) by coaxial cable
Maximum 30 Watts power with 100Mbps bandwidth
LEDs display transmission rate and PoE wattage
ED3638TR : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638T : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638R : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_top
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_bottom
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_back
產品介紹
產品亮點
產品規格
產品尺寸圖
訂購型號
影片專區

The ED3638 Hardened Ethernet Extender utilizes EtherWAN’s exclusive Power over Link (PoL) technology to deliver both PoE power and Ethernet communications over a single legacy coaxial cable. The ED3638 PoL solution is comprised of one transmitter and one receiver working together to provide reliable communications and power to remote PoE Powered Devices such as IP cameras, wireless access points, emergency intercoms, or VoIP phones.

With just the transmitter connected to power, the ED3638 provides a maximum of 30 watts of power and a bandwidth of 100Mbps to the ED3638 receiver, at distances up to 400 meters. Under this setup, transmission over longer distances can be achieved with lower data and power throughput — up to 1800 meters at a data rate of 15Mbps and 4 watts of power. However, for applications that require even longer distances, the ED3638 can be connected to power at both the transmitter and the receiver unit, increasing the transmission distance to a remarkable 2400 meters, with a data rate of 4Mbps and a full 30 watts. The current data transmission rate and power sourcing equipment output is displayed by LED indicators.

The ED3638 is highly resistant to electromagnetic interference, shock, and vibration, ensuring connection reliability even in harsh environments.

EtherWAN — "When Connectivity is Crucial."

Power over Link™ up to 1.8 km (5905 ft.)

» Over an 1800 meters long coaxial cable, a guaranteed 4 watts power with 15Mbps bandwidth is delivered to the receiving side

Ethernet extension solution with high transmission data rate up to 100Mbps

» Up to 400 meters transmission distance with 100Mbps data rate

Transmission rate and PSE output power indicator LEDs

» Six transmission rate LEDs and three PoE/PSE output power LEDs on the front panel

技術

標準

  • • IEEE 802.3 10BASE-T
  • • IEEE 802.3u 100BASE-TX,
  • • IEEE 802.3x full duplex and flow control
  • • IEEE 802.3af/at PoE/PSE

Protocols
  • • Transparent to higher layer protocols

傳輸型式
  • • IEEE 802.3x Full-duplex flow control


電源

輸入電壓

  • • Terminal Block: 46-57VDC
  • • DC JACK: 48VDC
  • [email protected] (Peak current 3.26A)

電力功耗
  • • Max. 65W with Power over Link (PoL) function enabled
  • • ED3638T: Max. 5W (without PoL/PoE)
  • • ED3638R: Max. 5W (without PoL/PoE), Max. 35W (with PoE only)

Protection
  • • Over current protection
  • • Reverse polarity protection


機構

機殼

  • • Aluminum case
  • • IP30

尺寸
  • • 50 x 110 x 135mm (W x D x H)
      (1.97" x 4.33" x 5.31")

重量
  • • 0.8Kg (1.76lbs.)

安裝方式
  • • DIN-Rail (Top hat type 35mm), Panel or Rack Mounting


介面

乙太網路埠

  • • ED3638T/R: 1 x RJ-45 port,10/100BASE-TX Full-duplex
  • • ED3638R: 1 x PoE/PSE port
  • • Auto-Negotiation, Auto-MDI/MDIX
  • • Speed: 10/100Mbps
  • • Distance: 100 meters (328ft.)
  • • Cable: 100BASE-TX: UTP CAT. 5 (4-pair wire)

Ethernet Extender Port
  • • Port: One 75Ω BNC Port (with F-type connector)
  • • Cable: Coaxial Cable (5C2V/RG6)
  • • Coaxial Cable (5C2V/RG6)

DIP Switch
  • • ED3638T: PoL: On/Off, Type: Perf/Std
  • • ED3638R: Mode: Loc/Rmt, Type: Perf/Std

LED 指示燈號
  • • Per Unit: Power Status (Power)
  • • Per Port 10/100TX: Link/Activity, Full-duplex
  • • Line Speed: Six indicators for 100/80/60/40/20Mbps and Link below 20Mbps
  • • PoE: Power over Ethernet function availability

Speed/Distance Reference
* PoL™ Enabled

Distance Data Rate ED3638R PoE Output
400m 100Mbps 30.0W
800m 60Mbps 15.4W
1000m 50Mbps 12.0W
1200m 45Mbps 8.0W
1600m 20Mbps 6.0W
1800m 15Mbps 4.0W


* PoL™ Disabled (Power Supply Applies on ED3638R)

Distance Data Rate ED3638R PoE Output
2000m 9Mbps 30.0W
2200m 6Mbps 30.0W
Up to 2400m 4Mbps 30.0W

環境

工作溫度

  • • -40 to 75°C (-40 to 167°F)
      Tested @ -40 to 85°C (-40 to 185°F)

儲存溫度
  • • -40 to 85°C (-40 to 185°F)

工作濕度
  • • 5% to 95% (無凝結)


通過認證

ISO

  • • Manufactured in an ISO 9001 facility

Safety
  • UL 60950-1
  • IEC 60950-1

EMI
  • FCC Part 15B Class A
  • EN 61000-6-4
  • EN 55022
  • EN 61000-3-2
  • EN 61000-3-3

EMS
  • EN 61000-6-2
    • • EN 61000-4-2 (ESD Standards)
    • • EN 61000-4-3 (Radiated RFI Standards)
    • • EN 61000-4-4 (Burst Standards)
    • • EN 61000-4-5 (Surge Standards)
    • • EN 61000-4-6 (Induced RFI Standards)
    • • EN 61000-4-8 (Magnetic Field Standards)

Environmental Test Compliance
  • IEC 60068-2-6 Fc (Vibration Resistance)
  • IEC 60068-2-27 Ea (Shock)
  • IEC 60068-2-32 Ed (Free Fall)


型號

ED3638 Hardened PoL/PoE Ethernet Extender over Coaxial Cable (Including one ED3638T and one ED3638R)

* ED3638T is the power transmitter of PoL and ED3638R is the power receiver of PoL.
* DIN-Rail mounting kit included.


Optional Power Supplies

EDR-120-48 120W/2.5A DIN-Rail 48VDC Industrial Power Supply
NDR-120-48 120W/2.5A DIN-Rail 48VDC Industrial Power Supply
SDR-480-48 480W/10A DIN-Rail 48VDC Industrial Power Supply

產品介紹

The ED3638 Hardened Ethernet Extender utilizes EtherWAN’s exclusive Power over Link (PoL) technology to deliver both PoE power and Ethernet communications over a single legacy coaxial cable. The ED3638 PoL solution is comprised of one transmitter and one receiver working together to provide reliable communications and power to remote PoE Powered Devices such as IP cameras, wireless access points, emergency intercoms, or VoIP phones.

With just the transmitter connected to power, the ED3638 provides a maximum of 30 watts of power and a bandwidth of 100Mbps to the ED3638 receiver, at distances up to 400 meters. Under this setup, transmission over longer distances can be achieved with lower data and power throughput — up to 1800 meters at a data rate of 15Mbps and 4 watts of power. However, for applications that require even longer distances, the ED3638 can be connected to power at both the transmitter and the receiver unit, increasing the transmission distance to a remarkable 2400 meters, with a data rate of 4Mbps and a full 30 watts. The current data transmission rate and power sourcing equipment output is displayed by LED indicators.

The ED3638 is highly resistant to electromagnetic interference, shock, and vibration, ensuring connection reliability even in harsh environments.

EtherWAN — "When Connectivity is Crucial."

產品亮點

Power over Link™ up to 1.8 km (5905 ft.)

» Over an 1800 meters long coaxial cable, a guaranteed 4 watts power with 15Mbps bandwidth is delivered to the receiving side

Ethernet extension solution with high transmission data rate up to 100Mbps

» Up to 400 meters transmission distance with 100Mbps data rate

Transmission rate and PSE output power indicator LEDs

» Six transmission rate LEDs and three PoE/PSE output power LEDs on the front panel

產品規格

技術

標準

  • • IEEE 802.3 10BASE-T
  • • IEEE 802.3u 100BASE-TX,
  • • IEEE 802.3x full duplex and flow control
  • • IEEE 802.3af/at PoE/PSE

Protocols
  • • Transparent to higher layer protocols

傳輸型式
  • • IEEE 802.3x Full-duplex flow control


電源

輸入電壓

  • • Terminal Block: 46-57VDC
  • • DC JACK: 48VDC
  • [email protected] (Peak current 3.26A)

電力功耗
  • • Max. 65W with Power over Link (PoL) function enabled
  • • ED3638T: Max. 5W (without PoL/PoE)
  • • ED3638R: Max. 5W (without PoL/PoE), Max. 35W (with PoE only)

Protection
  • • Over current protection
  • • Reverse polarity protection


機構

機殼

  • • Aluminum case
  • • IP30

尺寸
  • • 50 x 110 x 135mm (W x D x H)
      (1.97" x 4.33" x 5.31")

重量
  • • 0.8Kg (1.76lbs.)

安裝方式
  • • DIN-Rail (Top hat type 35mm), Panel or Rack Mounting


介面

乙太網路埠

  • • ED3638T/R: 1 x RJ-45 port,10/100BASE-TX Full-duplex
  • • ED3638R: 1 x PoE/PSE port
  • • Auto-Negotiation, Auto-MDI/MDIX
  • • Speed: 10/100Mbps
  • • Distance: 100 meters (328ft.)
  • • Cable: 100BASE-TX: UTP CAT. 5 (4-pair wire)

Ethernet Extender Port
  • • Port: One 75Ω BNC Port (with F-type connector)
  • • Cable: Coaxial Cable (5C2V/RG6)
  • • Coaxial Cable (5C2V/RG6)

DIP Switch
  • • ED3638T: PoL: On/Off, Type: Perf/Std
  • • ED3638R: Mode: Loc/Rmt, Type: Perf/Std

LED 指示燈號
  • • Per Unit: Power Status (Power)
  • • Per Port 10/100TX: Link/Activity, Full-duplex
  • • Line Speed: Six indicators for 100/80/60/40/20Mbps and Link below 20Mbps
  • • PoE: Power over Ethernet function availability

Speed/Distance Reference
* PoL™ Enabled

Distance Data Rate ED3638R PoE Output
400m 100Mbps 30.0W
800m 60Mbps 15.4W
1000m 50Mbps 12.0W
1200m 45Mbps 8.0W
1600m 20Mbps 6.0W
1800m 15Mbps 4.0W


* PoL™ Disabled (Power Supply Applies on ED3638R)

Distance Data Rate ED3638R PoE Output
2000m 9Mbps 30.0W
2200m 6Mbps 30.0W
Up to 2400m 4Mbps 30.0W

環境

工作溫度

  • • -40 to 75°C (-40 to 167°F)
      Tested @ -40 to 85°C (-40 to 185°F)

儲存溫度
  • • -40 to 85°C (-40 to 185°F)

工作濕度
  • • 5% to 95% (無凝結)


通過認證

ISO

  • • Manufactured in an ISO 9001 facility

Safety
  • UL 60950-1
  • IEC 60950-1

EMI
  • FCC Part 15B Class A
  • EN 61000-6-4
  • EN 55022
  • EN 61000-3-2
  • EN 61000-3-3

EMS
  • EN 61000-6-2
    • • EN 61000-4-2 (ESD Standards)
    • • EN 61000-4-3 (Radiated RFI Standards)
    • • EN 61000-4-4 (Burst Standards)
    • • EN 61000-4-5 (Surge Standards)
    • • EN 61000-4-6 (Induced RFI Standards)
    • • EN 61000-4-8 (Magnetic Field Standards)

Environmental Test Compliance
  • IEC 60068-2-6 Fc (Vibration Resistance)
  • IEC 60068-2-27 Ea (Shock)
  • IEC 60068-2-32 Ed (Free Fall)


產品尺寸圖

訂購型號

型號

ED3638 Hardened PoL/PoE Ethernet Extender over Coaxial Cable (Including one ED3638T and one ED3638R)

* ED3638T is the power transmitter of PoL and ED3638R is the power receiver of PoL.
* DIN-Rail mounting kit included.


Optional Power Supplies

EDR-120-48 120W/2.5A DIN-Rail 48VDC Industrial Power Supply
NDR-120-48 120W/2.5A DIN-Rail 48VDC Industrial Power Supply
SDR-480-48 480W/10A DIN-Rail 48VDC Industrial Power Supply

影片專區