Back to top

ED3638

広温度範囲対応産業用 10/100BASE-TX PoL™/PoE 同軸ケーブル イーサネット エクステンダー

PoE_30W
UL 60950
ED3638TR : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638T : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638R : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_top
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_bottom
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_back
PoLは同軸ケーブルで最大1.8km (590 ft) までイーサネット データと電力を伝送できます
最大30W電力と 100Mbps 帯域幅まで
伝送レートと電力出力表示のLED
ED3638TR : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638T : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638R : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_top
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_bottom
ED3638 : Hardened 10/100BASE-TX PoL™/PoE Ethernet Extender over Coaxial Cable_back
概要
特長
仕様
寸法図
製品型番
紹介動画

The ED3638 Hardened Ethernet Extender utilizes EtherWAN’s exclusive Power over Link (PoL) technology to deliver both PoE power and Ethernet communications over a single legacy coaxial cable. The ED3638 PoL solution is comprised of one transmitter and one receiver working together to provide reliable communications and power to remote PoE Powered Devices such as IP cameras, wireless access points, emergency intercoms, or VoIP phones.

With just the transmitter connected to power, the ED3638 provides a maximum of 30 watts of power and a bandwidth of 100Mbps to the ED3638 receiver, at distances up to 400 meters. Under this setup, transmission over longer distances can be achieved with lower data and power throughput — up to 1800 meters at a data rate of 15Mbps and 4 watts of power. However, for applications that require even longer distances, the ED3638 can be connected to power at both the transmitter and the receiver unit, increasing the transmission distance to a remarkable 2400 meters, with a data rate of 4Mbps and a full 30 watts. The current data transmission rate and power sourcing equipment output is displayed by LED indicators.

The ED3238 is highly resistant to electromagnetic interference, shock, and vibration, ensuring connection reliability even in harsh environments.

EtherWAN — "When Connectivity is Crucial."

Power over Link™ up to 1.8 km (5905 ft.)

» Over an 1800 meters long coaxial cable, a guaranteed 4 watts power with 15Mbps bandwidth is delivered to the receiving side

Ethernet extension solution with high transmission data rate up to 100Mbps

» Up to 400 meters transmission distance with 100Mbps data rate

Transmission rate and PSE output power indicator LEDs

» Six transmission rate LEDs and three PoE/PSE output power LEDs on the front panel

Technology

Standards

  • • IEEE802.3 10BASE-T
  • • IEEE802.3u 100BASE-TX,
  • • IEEE802.3x, full duplex and flow control
  • • IEEE802.3af/at PoE/PSE

Protocols
  • • Transparent to higher layer protocols

Processing Type
  • • IEEE802.3x Full-duplex flow control

 


Power

Input

  • • Terminal Block: 46 - 57VDC
  • • DC JACK: 48VDC
  • • 2.5A @ 48VDC (Peak current 3.26A)

Power Consumption
  • • Max. 65W with Power over Link (PoL) function enabled
  • • ED3638T: Max. 5W (without PoL / PoE)
  • • ED3638R: Max. 5W (without PoL / PoE)Max. 35W (with PoE only)

Protection
  • • Over current protection
  • • Reverse polarity protection

 


Mechanical

Casing

  • • Aluminum case
  • • IP30

Dimensions
  • • 50 x 110 x 135mm (W x D x H)
      (1.97" x 4.33" x 5.31")

Weight
  • • 0.8Kg (1.76lbs.)

Installation
  • • DIN-Rail (Top hat type 35mm), Panel, Rack Mounting

 


Interface

Ethernet Port

  • • ED3638T/R: 1x RJ-45 port,10/100BASE-TX Full-duplex
  • • ED3638R: 1x PoE/PSE port
  • • Auto-Negotiation, Auto-MDI/MDIX
  • • Speed: 10/100Mbps
  • • Distance: 100meters (328ft.)
  • • Cable: 100BASE-TX: UTP CAT. 5 (4-pair wire)

Ethernet Extender Port
  • • Port: One 75Ω BNC Port (with F-type connector)
  • • Cable: Coaxial Cable (5C2V / RG6)
  • • Coaxial Cable (5C2V / RG6)

DIP Switch
  • • ED3638T: PoL: ON/OFF, Type: Perf/Std
  • • ED3638R: Mode: Loc/Rmt, Type: Perf/Std

LED Indicators
  • • Per Unit: Power Status (Power)
  • • Per Port 10/100TX: Link/Activity, Full-duplex
  • • Line Speed: Six indicators for 100/80/60/40/20Mbps and Link below 20Mbps
  • • PoE: Power over Ethernet function availability

 

Speed / Distance Reference
PoL™ Enabled

Distance Data Rate ED3638R PoE Output
400m 100Mbps 30.0W
800m 60Mbps 15.4W
1000m 50Mbps 12.0W
1200m 45Mbps 8.0W
1600m 20Mbps 6.0W
1800m 15Mbps 4.0W

PoL™ Disabled
(Power Supply Applies on ED3638R)

Distance Data Rate ED3638R PoE Output
2000m 9Mbps 30.0W
2200m 6Mbps 30.0W
Up to 2400m 4Mbps 30.0W

Environment

Operating Temperature

  • • -40 to 75°C (-40 to 167°F)
      Tested @ -40 to 85°C (-40 to 185°F)

Storage Temperature
  • • -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity
  • • 5% to 95% (non-condensing)

 


Regulatory Approvals

ISO

  • • Manufactured in an ISO 9001 facility

Safety
  • UL 60950-1
  • IEC 60950-1

EMI
  • FCC Part 15B, Class A
  • EN 61000-6-4
  • EN 55022
  • EN 61000-3-2
  • EN 61000-3-3

EMS
  • EN 61000-6-2
    • • EN 61000-4-2 (ESD Standards)
    • • EN 61000-4-3 (Radiated RFI Standards)
    • • EN 61000-4-4 (Burst Standards)
    • • EN 61000-4-5 (Surge Standards)
    • • EN 61000-4-6 (Induced RFI Standards)
    • • EN 61000-4-8 (Magnetic Field Standards)

Environmental Test Compliance
  • IEC 60068-2-6 Fc (Vibration Resistance)
  • IEC 60068-2-27 Ea (Shock)
  • IEC 60068-2-32 Ed (Free Fall)

 


Model

ED3638 Hardened PoL/PoE Ethernet Extender over Coaxial Cable (including one ED3638T and one ED3638R)

Note:
* ED3638T is PoL Transceiver and ED3638R is PoL Receiver
* DIN-Rail mounting kit included


Optional Power Supplies

Power supply suggestion 30-watt PoE application
SDR-120-48 / DR-120-48 (120W 48VDC) For one pair
SDR-240-48 (240W 48VDC) For three pairs
SDR-480-48 (480W 48VDC) For seven pairs

概要

The ED3638 Hardened Ethernet Extender utilizes EtherWAN’s exclusive Power over Link (PoL) technology to deliver both PoE power and Ethernet communications over a single legacy coaxial cable. The ED3638 PoL solution is comprised of one transmitter and one receiver working together to provide reliable communications and power to remote PoE Powered Devices such as IP cameras, wireless access points, emergency intercoms, or VoIP phones.

With just the transmitter connected to power, the ED3638 provides a maximum of 30 watts of power and a bandwidth of 100Mbps to the ED3638 receiver, at distances up to 400 meters. Under this setup, transmission over longer distances can be achieved with lower data and power throughput — up to 1800 meters at a data rate of 15Mbps and 4 watts of power. However, for applications that require even longer distances, the ED3638 can be connected to power at both the transmitter and the receiver unit, increasing the transmission distance to a remarkable 2400 meters, with a data rate of 4Mbps and a full 30 watts. The current data transmission rate and power sourcing equipment output is displayed by LED indicators.

The ED3238 is highly resistant to electromagnetic interference, shock, and vibration, ensuring connection reliability even in harsh environments.

EtherWAN — "When Connectivity is Crucial."

特長

Power over Link™ up to 1.8 km (5905 ft.)

» Over an 1800 meters long coaxial cable, a guaranteed 4 watts power with 15Mbps bandwidth is delivered to the receiving side

Ethernet extension solution with high transmission data rate up to 100Mbps

» Up to 400 meters transmission distance with 100Mbps data rate

Transmission rate and PSE output power indicator LEDs

» Six transmission rate LEDs and three PoE/PSE output power LEDs on the front panel

仕様

Technology

Standards

  • • IEEE802.3 10BASE-T
  • • IEEE802.3u 100BASE-TX,
  • • IEEE802.3x, full duplex and flow control
  • • IEEE802.3af/at PoE/PSE

Protocols
  • • Transparent to higher layer protocols

Processing Type
  • • IEEE802.3x Full-duplex flow control

 


Power

Input

  • • Terminal Block: 46 - 57VDC
  • • DC JACK: 48VDC
  • • 2.5A @ 48VDC (Peak current 3.26A)

Power Consumption
  • • Max. 65W with Power over Link (PoL) function enabled
  • • ED3638T: Max. 5W (without PoL / PoE)
  • • ED3638R: Max. 5W (without PoL / PoE)Max. 35W (with PoE only)

Protection
  • • Over current protection
  • • Reverse polarity protection

 


Mechanical

Casing

  • • Aluminum case
  • • IP30

Dimensions
  • • 50 x 110 x 135mm (W x D x H)
      (1.97" x 4.33" x 5.31")

Weight
  • • 0.8Kg (1.76lbs.)

Installation
  • • DIN-Rail (Top hat type 35mm), Panel, Rack Mounting

 


Interface

Ethernet Port

  • • ED3638T/R: 1x RJ-45 port,10/100BASE-TX Full-duplex
  • • ED3638R: 1x PoE/PSE port
  • • Auto-Negotiation, Auto-MDI/MDIX
  • • Speed: 10/100Mbps
  • • Distance: 100meters (328ft.)
  • • Cable: 100BASE-TX: UTP CAT. 5 (4-pair wire)

Ethernet Extender Port
  • • Port: One 75Ω BNC Port (with F-type connector)
  • • Cable: Coaxial Cable (5C2V / RG6)
  • • Coaxial Cable (5C2V / RG6)

DIP Switch
  • • ED3638T: PoL: ON/OFF, Type: Perf/Std
  • • ED3638R: Mode: Loc/Rmt, Type: Perf/Std

LED Indicators
  • • Per Unit: Power Status (Power)
  • • Per Port 10/100TX: Link/Activity, Full-duplex
  • • Line Speed: Six indicators for 100/80/60/40/20Mbps and Link below 20Mbps
  • • PoE: Power over Ethernet function availability

 

Speed / Distance Reference
PoL™ Enabled

Distance Data Rate ED3638R PoE Output
400m 100Mbps 30.0W
800m 60Mbps 15.4W
1000m 50Mbps 12.0W
1200m 45Mbps 8.0W
1600m 20Mbps 6.0W
1800m 15Mbps 4.0W

PoL™ Disabled
(Power Supply Applies on ED3638R)

Distance Data Rate ED3638R PoE Output
2000m 9Mbps 30.0W
2200m 6Mbps 30.0W
Up to 2400m 4Mbps 30.0W

Environment

Operating Temperature

  • • -40 to 75°C (-40 to 167°F)
      Tested @ -40 to 85°C (-40 to 185°F)

Storage Temperature
  • • -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity
  • • 5% to 95% (non-condensing)

 


Regulatory Approvals

ISO

  • • Manufactured in an ISO 9001 facility

Safety
  • UL 60950-1
  • IEC 60950-1

EMI
  • FCC Part 15B, Class A
  • EN 61000-6-4
  • EN 55022
  • EN 61000-3-2
  • EN 61000-3-3

EMS
  • EN 61000-6-2
    • • EN 61000-4-2 (ESD Standards)
    • • EN 61000-4-3 (Radiated RFI Standards)
    • • EN 61000-4-4 (Burst Standards)
    • • EN 61000-4-5 (Surge Standards)
    • • EN 61000-4-6 (Induced RFI Standards)
    • • EN 61000-4-8 (Magnetic Field Standards)

Environmental Test Compliance
  • IEC 60068-2-6 Fc (Vibration Resistance)
  • IEC 60068-2-27 Ea (Shock)
  • IEC 60068-2-32 Ed (Free Fall)

 


寸法図

製品型番

Model

ED3638 Hardened PoL/PoE Ethernet Extender over Coaxial Cable (including one ED3638T and one ED3638R)

Note:
* ED3638T is PoL Transceiver and ED3638R is PoL Receiver
* DIN-Rail mounting kit included


Optional Power Supplies

Power supply suggestion 30-watt PoE application
SDR-120-48 / DR-120-48 (120W 48VDC) For one pair
SDR-240-48 (240W 48VDC) For three pairs
SDR-480-48 (480W 48VDC) For seven pairs

紹介動画