ED3538T/R Dip Switch Configuration
Answer:
To enable both the power and data communications between the ED3538T and ED3538R, the DIP switches on both must be configured according to the following:
For technical support questions please email: [email protected] or call 714-779-3800
- The “PoL” DIP switch #1 on the ED3538T must be configured to be in the “On” or up position to enable power to transfer from the ED3538T to the ED3538R.
- The “Mode” DIP switch #1 on the ED3538R must be configured to be in the “Rmt” or up position to accept data communications from the ED3538T.
- The “Type” DIP switch #2 on both the ED3538T and ED3538R should be configured in the “Std” or down position, in order to establish an initial stable connection.
- Optionally, the “Type” DIP switch #2 on both the ED3538T and ED3538R can be configured in the “Perf” or up position, to optimize the data and sync rate.
ED3538T: DIP Sw #1 up “On”, DIP Sw #2 down “Std”
ED3538R: DIP Sw #1 up “Rmt”, DIP Sw #2 down “Std”