What is Ethernet Extender?


Upgrading an access control and/or surveillance system with new systems that communicate using IP technology can be a monumental task. The system has been communicating between devices using serial communications RS232, RS422 or RS485 and the cameras have been connecting over coaxial cable. New cameras, keypads, badge readers and other devices connect using Ethernet which is connected over Category 5 – Category 6 twisted pair wire. Changing the wiring infrastructure can be more costly and time consuming than upgrading the entire system.

 

EtherWAN offers a solution to this dilemma. EtherWAN has developed a line of Ethernet extenders that provide Ethernet connectivity over existing coaxial cable or plain old telephone/communications cable. EtherWAN's ED3501 and ED3541 Ethernet extenders will work whether your cable is 26 AWG, 19 AWG or somewhere in between twisted or straight wire. Using Ethernet extenders is significantly lower in cost than replacing a cable plant and extends the life of your installed infrastructure.

 

The model lineup of Ethernet extension Solutions 

 

Extending Ethernet over One Pair of Wires, Twisted or Straight (24ga to 19ga)

 Speed Chart

 
Mbps Distance
50 300 m
40 600 m
30 700 m
25 800 m
20 1,000 m
15 1,200 m
10 1,400 m
5 1,600 m
3 1,800 m
1 1,900 m

 

 

product_ed3501.jpg

ED3501 Ethernet Extender

1 Ethernet Port 10/100TX RJ45
1 Extension Port 1 Pair Wire RJ11
Industrial Grade -10⁰C to 60⁰C Operating Temperature Range
Wall Mount or Chassis Mount using EtherWAN's EMC1600 Chassis
Power Cube Included 100VAC – 240VAC 

product_ed3541.jpg

ED3541 Ethernet Extender (Hardened) 

1 Ethernet Port 10/100TX RJ45
1 Extension Port 1 Pair Wire RJ11 or Terminal Block
Hardened Grade -40⁰C to 75⁰C Operating Temperature
DIN Rail, Wall or Shelf Mount
Power 12VDC to 48VDC Terminal Block or DC Jack 

 

 

 


 

How do these products work?

Plug and play, connect any of the ED3501 and ED3541 on one end of the wire and set the selection switch to Local. Then connect another unit, any of the three, to the other end of the wire and set the selection switch to Remote. Apply power and they will sync up in a few seconds and your running with an Ethernet Link.

 

The same procedure is used for the coaxial units (ED3331 and ED3341). Two of these units communicate with each other providing an Ethernet port at both ends of the cable.

 DON’T CHANGE THAT CABLE – USE ETHERNET EXTENDERS. 

 

Industrial 10/100BASE-TX Ethernet Extender over Coaxial Cable

ED3331 Ethernet Extender

1 Ethernet Port 10/100TX RJ45
1 Extension Port 1 Coaxial
Industrial Grade -10⁰C to 60⁰C Operating Temperature Range
Wall Mount or Chassis Mount using EtherWAN’s EMC1600 Chassis
Power Cube Included 100VAC – 240VAC

Hardened 10/100BASE-TX Ethernet Extender over Coaxial Cable

ED3341 Ethernet Extender over Coaxial Cable  (Hardened)

1 Ethernet Port 10/100TX RJ45
1 Extension Port 1 Coaxial
Hardened Grade -40⁰C to 70⁰C Operating Temperature
DIN Rail, Wall or Shelf Mount
Power 12VDC to 48VDC Terminal Block or DC Jack

 


 