Technology
Standards
IEEE802.3 10BASE-T,IEEE802.3u 100BASE-TX/100BASE-FX, IEEE802.3x
Forward and Filtering Rate
14,880pps for 10Mbps
148,810pps for 100Mbps
Packet Buffer Memory
128K bits
Processing Type
Store-and-Forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Power
Input
Input Voltage: 12 to 48VDC (Terminal Block)/12VDC(DC Jack)
Power Consumption
2.4W MAX. 0.2A @ 12VDC, 0.05A @ 48VDC
Overload Current Protection
Present
Reverse Polarity Protection
Present
Mechanical
Casing
Aluminum case
IP30
Dimensions
50mm (W) x 110mm (D) x 135mm (H)
(1.97" (W) x 4.33" (D) x 5.31" (H))
Weight
0.8Kg (1.76lbs.)
Installation
DIN-Rail (Top hat type 35mm), Panel, Rack Mounting
Interface
Ethernet Port
10/100BASE-TX: 1 port
100BASE-FX: 1 port
LED Indicators
Per Unit:Power Status (Power 1, Power 2, Fault),Link-Fault-Pass-Through
Per Port: 10/100TX: Link/Activity, Full-duplex/Collision,Speed
100FX: Link/Activity, Full-duplex/Collision
Relay Contact
Relay contact rating with current 1A @ 30VDC,0.5A @ 120VAC
Environment
Operating Temperature
-40°C to 75°C (-40°F to 167°F)
Tested @ -40°C to 85°C (-40°F to 185°F)
Storage Temperature
-40°C to 85°C(-40°F to 185°F)
Ambient Relative Humidity
5% to 95% (non-condensing)
Regulatory Approvals
ISO
Manufactured in an ISO9001 facility
Safety
UL508
EMI
FCC Part 15, Class A
EN61000-6-4
- EN55022
- EN61000-3-2
- EN61000-3-3
EMS
IEC61850-3 & IEEE1613: Substation & Power automation Applications
EN50121-4: Railway Applications
EN61000-6-2
- EN61000-4-2 (ESD Standards)
Contact: + / - 8KV; Criteria B
Air: + / - 15KV; Criteria B
- EN61000-4-3 (Radiated RFI Standards)
35V/m, 80 to 1000MHz; 80% AM Criteria A
- EN61000-4-4 (Burst Standards)
Signal Ports: + / - 4KV; Criteria A
D.C. Power Ports: + / - 4KV; Criteria A
- EN61000-4-5 (Surge Standards)
Signal Ports: + / - 2KV; Line-to-Line; Criteria A
D.C. Power Ports: + / - 2KV; Line-to-earth; Criteria A
- EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10Vrms @ 0.15 - 80MHz; 80% AM Criteria A
D.C. Power Ports: 10Vrms @ 0.15 - 80MHz; 80% AM
Criteria A
- EN61000-4-8 (Magnetic Field Standards)
1000A/m @ 50, 60Hz; Criteria A
Environmental
Test Compliance
IEC60068-2-6 Fc (Vibration Resistance)
5g @ 10 - 150Hz, Amplitude 0.35mm (Operation/Storage/Transport)
IEC60068-2-27 Ea (Shock)
25g @ 11ms (Half-Sine Shock Pulse; Operation)
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
IEC60068-2-32 Ed (Free Fall)
1M (3.281ft.)